123 lines
2.7 KiB
Bash
Executable File
123 lines
2.7 KiB
Bash
Executable File
#!/bin/sh
|
|
### BEGIN INIT INFO
|
|
# Provides: dbus
|
|
# Required-Start: $remote_fs $syslog
|
|
# Required-Stop: $remote_fs $syslog
|
|
# Default-Start: 2 3 4 5
|
|
# Default-Stop:
|
|
# Short-Description: D-Bus systemwide message bus
|
|
# Description: D-Bus is a simple interprocess messaging system, used
|
|
# for sending messages between applications.
|
|
### END INIT INFO
|
|
# -*- coding: utf-8 -*-
|
|
# Debian init.d script for D-BUS
|
|
# Copyright © 2003 Colin Walters <walters@debian.org>
|
|
# Copyright © 2005 Sjoerd Simons <sjoerd@debian.org>
|
|
|
|
set -e
|
|
|
|
DAEMON=/usr/bin/dbus-daemon
|
|
UUIDGEN=/usr/bin/dbus-uuidgen
|
|
UUIDGEN_OPTS=--ensure
|
|
NAME=dbus
|
|
DAEMONUSER=messagebus
|
|
PIDDIR=/var/run/dbus
|
|
PIDFILE=$PIDDIR/pid
|
|
DESC="system message bus"
|
|
|
|
test -x $DAEMON || exit 0
|
|
|
|
. /lib/lsb/init-functions
|
|
|
|
# Source defaults file; edit that file to configure this script.
|
|
PARAMS=""
|
|
if [ -e /etc/default/dbus ]; then
|
|
. /etc/default/dbus
|
|
fi
|
|
|
|
create_machineid() {
|
|
# Create machine-id file
|
|
if [ -x $UUIDGEN ]; then
|
|
$UUIDGEN $UUIDGEN_OPTS
|
|
fi
|
|
}
|
|
|
|
start_it_up()
|
|
{
|
|
if [ ! -d $PIDDIR ]; then
|
|
mkdir -p $PIDDIR
|
|
chown $DAEMONUSER $PIDDIR
|
|
chgrp $DAEMONUSER $PIDDIR
|
|
fi
|
|
|
|
if ! mountpoint -q /proc/ ; then
|
|
log_failure_msg "Can't start $DESC - /proc is not mounted"
|
|
return
|
|
fi
|
|
|
|
if [ -e $PIDFILE ]; then
|
|
if $0 status > /dev/null ; then
|
|
log_success_msg "$DESC already started; not starting."
|
|
return
|
|
else
|
|
log_success_msg "Removing stale PID file $PIDFILE."
|
|
rm -f $PIDFILE
|
|
fi
|
|
fi
|
|
|
|
create_machineid
|
|
|
|
log_daemon_msg "Starting $DESC" "$NAME"
|
|
start-stop-daemon --start --quiet --pidfile $PIDFILE \
|
|
--exec $DAEMON -- --system $PARAMS
|
|
log_end_msg $?
|
|
}
|
|
|
|
shut_it_down()
|
|
{
|
|
log_daemon_msg "Stopping $DESC" "$NAME"
|
|
start-stop-daemon --stop --retry 5 --quiet --oknodo --pidfile $PIDFILE \
|
|
--user $DAEMONUSER
|
|
# We no longer include these arguments so that start-stop-daemon
|
|
# can do its job even given that we may have been upgraded.
|
|
# We rely on the pidfile being sanely managed
|
|
# --exec $DAEMON -- --system $PARAMS
|
|
log_end_msg $?
|
|
rm -f $PIDFILE
|
|
}
|
|
|
|
reload_it()
|
|
{
|
|
create_machineid
|
|
log_action_begin_msg "Reloading $DESC config"
|
|
dbus-send --print-reply --system --type=method_call \
|
|
--dest=org.freedesktop.DBus \
|
|
/ org.freedesktop.DBus.ReloadConfig > /dev/null
|
|
# hopefully this is enough time for dbus to reload it's config file.
|
|
log_action_end_msg $?
|
|
}
|
|
|
|
case "$1" in
|
|
start)
|
|
start_it_up
|
|
;;
|
|
stop)
|
|
shut_it_down
|
|
;;
|
|
reload|force-reload)
|
|
reload_it
|
|
;;
|
|
restart)
|
|
shut_it_down
|
|
start_it_up
|
|
;;
|
|
status)
|
|
status_of_proc -p $PIDFILE $DAEMON $NAME && exit 0 || exit $?
|
|
;;
|
|
*)
|
|
echo "Usage: /etc/init.d/$NAME {start|stop|reload|restart|force-reload|status}" >&2
|
|
exit 2
|
|
;;
|
|
esac
|
|
|